AH15 - Wiegand DIP Switch Configuration Table
| DIP SWITCH NUMBER | LABEL | DESCRIPTION |
|---|---|---|
| 1 | A0 |
Controls use of Red LED signal for access decision. ON => Red LED is used. OFF => Red LED is ignored. |
| 2 | A1 | Set to OFF by default. Reserved for future use. |
| 3 | A2 |
Controls addition of parity bits if required. ON => Addition of parity bits is enabled. OFF => Addition of parity bits is disabled. Credentials are transmitted as received. |
| 4 | A3 |
Controls byte order of transmitted credentials. ON => The byte order is reversed on the Wiegand interface compared to what is received from the Aperio® lock. OFF => The byte order is left as is. |
| 5 | A4 |
Used in “Pairing Mode” ON => Starts in Pairing Mode OFF => Normal use |
| 6-8 | Not used for Wiegand |