Communication Hub hardware version AH20 has four Wiegand signals plus power supply. The purpose and connection of these signals are described in the table below.

Table 1. AH20 Connectors (J100)
HUB CONNECTOR DESCRIPTION
DATA 1 Wiegand Data 1 signal. Output from Communication Hub. Used to transmit credentials.
DATA 0 Wiegand Data 0 signal. Output from Communication Hub. Used to transmit credentials.
RED Wiegand Red LED signal. Input to Communication Hub. Used for access decision. Leave unconnected if DIP switch 1 is selected “OFF”. Signal is active low.
GREEN Wiegand Green LED signal. Input to Communication Hub. Used for access decision. Signal is active low. See DIP 1 for alternate instructions.
GND GND = Signal ground. Should be connected to EAC system GND and power supply GND.
8-24 VDC Power supply input, 8-24 VDC, 2 W.