Low frequency

../../images/progappbilder/image38.png
In the list, select the low frequency credential type to use:
  • HID Prox
  • EM Prox
Note: This credential type cannot be used together with any other credential types.
Note: The following information is not applicable for the US market:

Before the lock/sensor has been configured with the Programming Application, the lock/ sensor will accept any Low Frequency credential technology.

Once the lock has read any credential technology 3 times the lock/sensor will only accept this technology. If the power is toggled the lock/sensor will return to the initial state of ac- cepting any credential.

Once a specific credential technology has been configured via the Programming Applica- tion, this will be the only accepted type of credential. The lock will remain in this condition after the power has been toggled.