Details for the Wiegand interface signals:

| DIP | Abbr. | Description |
|---|---|---|
| 8 | TERM | Not applicable for Wiegand. Set to OFF. |
| 7 | UP | Not applicable for Wiegand. Set to OFF. |
| 6 | DOWN | Not applicable for Wiegand. Set to OFF. |
| 5 | A4 | ON = Starts in pairing mode. OFF = Normal use. |
| 4 | A3 | Controls byte order of transmitted credentials. OFF => The byte order is left as is. ON => The byte order is reversed compared to what is received as input to the Hub Wiegand EAC interface component. |
| 3 | A2 | Controls addition of parity bits on transmitted credentials. One even parity bit before and one odd parity bit after the actual credentials. OFF =>Addition of parity is disabled. Credentials are transmitted as received. ON => Addition of parity bits is enabled. |
| 2 | A1 | Reserved for future use. Set to OFF. |
| 1 | A0 | Controls use of Red LED signal for access decision. ON = Red LED is used. OFF = Red LED is ignored. |